Bruna Bacalja, Maja Krčum,
Tomislav Peša, Marko Zubčić
University of Split (Croatia)
https://doi.org/10.53656/ped21-6s.16mea
Abstract. This paper presents the measurement process of the emissions from marine diesel engines. The emission measurement was carried out by the certified TESTO 350 Maritime exhaust gas analyzer on the Juraj Dalmatinac ferry Caterpillar C32 engines. The gas analyzer records the concentrations of nitrogen oxides (NOx), carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2) and sulfur dioxide (SO2). TESTO 350 emission sampling probe was set at the end of the exhaust pipe. A combustion emission measurement was performed during a Split – Supetar (Brač) trip and backwards with the total duration of 110 min. The emissions are estimated for two trip phases: “maneuvering” and “at sea”.
Keywords: emission measurement; exhaust gas analyzer; marine ports; marine diesel engines